Equipment Type |
Minimum Efficiency Level for units purchased on or after April 1, 2009
|
Sizing and Selection |
Customer Portion of Incentive |
|
Central Air Conditioning, Air to Air Heat Pump or Ductless Mini-Split** A/C System or Heat Pump
|
Compressor and coil
combination that yield >= SEER 14.5 and EER 12 and (in the case of heat pumps) HSPF 8.5
|
ACCA Manual J and Manual S outputs are required showing that the installed system is sized within 15% variance of requirement and correctly selected for the dwelling
|
$300 |
|
Central Air Conditioning, Air to Air Heat Pump or Ductless Mini-Split** A/C System or Heat Pump
|
Compressor and coil
combination that yield >= SEER 15 and EER 12.5 and (in the case of heat pumps) HSPF 8.5
|
ACCA Manual J and Manual S outputs are required showing that the installed system is sized within 15% variance of requirement and correctly selected for the dwelling
|
$400 |
|
Central Air Conditioner, Air to Air Heat Pump or Ductless Mini-Split** A/C System or Heat Pump
|
Compressor and coil
combination that yield >=SEER 16 and EER 13 and (in the case of heat pumps) HSPF 8.5
|
ACCA Manual J and Manual S outputs are required showing that the installed system is sized within 15% variance of requirement and correctly selected for the dwelling
|
$600 |
|
Geothermal Heat Pump
|
GSHP systems must be ENERGY STARŪ qualified to be eligible for incentives.
|
ACCA Manual J and Manual S outputs are required showing that the installed system is sized within 15% variance of requirement and correctly selected for the dwelling
|
$150 |
*SEER (Seasonal Energy Efficiency Ratio) ** EER (Energy Efficiency Ratio) ***HSPF (Heating Seasonal Performance Factor)
** ACCA Manual J and Manual S outputs are not required for Ductless Mini-Split Systems.